Acid Proofing / Acid Resistant Tiles

Heavy Duty 200mm Acid Resistant Tiles

Heavy Duty 200mm is a grade in Shanker Agencies’ acid resistant tiles range.

Heavy Duty 200mm grade acid resistant tiles supplied by Shanker Agencies
Grade
Heavy Duty 200mm

Heavy Duty 200mm technical specification

Typical values for Heavy Duty 200mm acid resistant tiles. Test methods vary by property and product family, so confirm the applicable standard against the manufacturer datasheet before specifying.

PropertyHeavy Duty 200mm
Size200×200×20mm
Water absorption<0.5%
Acid resistance99%
FinishSmooth
Typical useHigh-traffic chemical floors

Where Heavy Duty 200mm is used

Chemical plant floor areas
Effluent treatment plant floor & walls
Laboratory benches and floors
Battery charging rooms
Pickle line floor (steel plants)
Pharma clean-room floors
Drainage channel invert lining
Loading bay floors (chemical spill protection)

Full acid resistant tiles range

Compare Heavy Duty 200mm against every grade SAPL stocks in this family.

GradeSizeWater absorptionAcid resistanceFinishTypical use
Standard 150mm150×150×10mm<0.5%99%SmoothGeneral chemical floor
Heavy Duty 200mm200×200×20mm<0.5%99%SmoothHigh-traffic chemical floors
Anti-Skid150×150×10mm<0.5%99%TexturedWet areas, walkways
Channel InvertCustom<0.5%99%SmoothEffluent channel invert

Installation notes

  1. 1Substrate: smooth, level concrete (± 3mm in 3m), grind high spots, fill low spots with epoxy mortar
  2. 2Use only acid-resistant tile adhesive mortar (furan-based for strong acids, potassium silicate for milder duty)
  3. 3Lay tiles with minimum 3mm joint width, do not butt joint
  4. 4Grout all joints with acid-resistant grout immediately after tile adhesive has set (24–48 hrs)
  5. 5Seal around drains and wall junctions with acid-resistant flexible sealant
  6. 6Cure for 5–7 days before any chemical exposure
  7. 7Test: cover with dilute acid solution for 24 hours before commissioning

Disclaimer: values are typical and compiled by Shanker Agencies Pvt. Ltd. from standard industry data and published manufacturer specifications. They are indicative, not a guarantee. Confirm the exact grade datasheet before specifying. For a certified datasheet or quotation, contact info@shankeragencies.com or +91 98999 57888.