Acid Proofing / Acid Proof Bricks

Class II Acid Proof Bricks

Class II is a grade in Shanker Agencies’ acid proof bricks range.

Class II grade acid proof bricks supplied by Shanker Agencies
Grade
Class II
Cold crushing strength
50 MPa

Class II technical specification

Typical values for Class II acid proof bricks. Test methods vary by property and product family, so confirm the applicable standard against the manufacturer datasheet before specifying.

Water absorption
<2%
Acid resistance
99% min
Alkali resistance
85%
Cold crushing strength
50 MPa
Size
230×113×65mm std

Where Class II is used

Acid storage tank lining (H₂SO₄, HNO₃, HCl, H₃PO₄)Reaction vessel and reactor liningAbsorption tower internal liningChimney and flue gas duct liningEffluent treatment plant sumps and channelsFertiliser plant, sulphuric acid plantPickling tank lining (steel processing)Battery room floors
Compare Class II with other grades▾

Compare Class II against every grade SAPL stocks in this family.

Swipe to compare grades

GradeWater absorptionAcid resistanceAlkali resistanceCold crushing strengthSize
Class I3-6%97% min75%40 MPa230×113×65mm std
Class IIthis grade<2%99% min85%50 MPa230×113×65mm std
Class III<0.5%99.5% min90%55 MPaCustom
Carbon-Fill<1%99.5% min95%45 MPaStandard + custom
Anti-static<2%99% min85%45 MPa230×113×65mm std

Send the drawing, dimensions, application and quantity for Class II acid proof bricks. Our technical team reviews the requirement and advises on grade and fulfilment route.

Request Class II Quote

Installation notes

  1. 1Surface preparation: concrete or steel substrate must be clean, dry, and free of oil/grease
  2. 2Apply primer coat, epoxy primer for steel, concrete primer for concrete substrate
  3. 3Use appropriate acid-resistant cement: furan resin (best acid resistance), phenolic resin, or potassium silicate
  4. 4Bed mortar thickness: 3–6 mm, applied to both brick and substrate (buttered joint)
  5. 5Joint width: 3–6 mm, fully filled with acid-resistant mortar
  6. 6Curing: furan resin mortars, 24 hrs at 25°C before any chemical exposure; heat curing improves performance
  7. 7Test before commissioning: hydraulic leak test or chemical spot test

Disclaimer: values are typical and compiled by Shanker Agencies Pvt. Ltd. from standard industry data and published manufacturer specifications. They are indicative, not a guarantee. Confirm the exact grade datasheet before specifying. For a certified datasheet or quotation, contact info@shankeragencies.com or +91 98999 57888.