Insulation / Ceramic Fiber Products

1600 Module Ceramic Fiber Products

1600 Module is a grade in Shanker Agencies’ ceramic fiber products range.

1600 Module grade ceramic fiber products supplied by Shanker Agencies
Grade
1600 Module
Max service temperature
1600°C
Bulk density
160-200 kg/m³

1600 Module technical specification

Typical values for 1600 Module ceramic fiber products. Test methods vary by property and product family, so confirm the applicable standard against the manufacturer datasheet before specifying.

Property1600 Module
Max service temperature1600°C
Bulk density160-200 kg/m³
Thermal conductivity at 500°C0.12 W/mK
Tensile strength
FormModule (300×300mm)

Where 1600 Module is used

Car-bottom and bogie hearth furnace lining
Continuous annealing furnace roof & walls
Heat treatment furnace complete lining
Backup insulation in steel ladle covers
Expansion joints in kiln linings
Petrochemical reformer furnace casing insulation
Torpedo car cover insulation
Industrial boiler casing insulation

Full ceramic fiber products range

Compare 1600 Module against every grade SAPL stocks in this family.

GradeMax service temperatureBulk densityThermal conductivity at 500°CTensile strengthForm
1260 Blanket1260°C96-128 kg/m³0.08 W/mK30 kPaRoll (7.3m × 610mm)
1400 Blanket1400°C96-128 kg/m³0.10 W/mK35 kPaRoll (7.3m × 610mm)
1600 Module1600°C160-200 kg/m³0.12 W/mKModule (300×300mm)
1260 Board1260°C300-350 kg/m³0.12 W/mK200 kPaSheet (1000×500mm)
Vacuum Formed1400°C350-400 kg/m³0.14 W/mK300 kPaCustom shapes
Ceramic Paper1260°C160-200 kg/m³0.10 W/mKRoll (5m × 300mm)

Installation notes

  1. 1Blanket: wrap around cylindrical vessels or layer on flat surfaces, overlap joints by 50 mm
  2. 2Modules: attach to shell plate using stud welding, butt joints, no gaps
  3. 3Boards: cut with hand saw or angle grinder, wear respiratory protection when cutting fibres
  4. 4Expansion gaps: ceramic fiber requires no expansion gaps (it compresses and expands freely)
  5. 5Anchoring: stainless steel stud anchors every 300–400 mm for overhead and vertical applications
  6. 6Vapour barrier: apply rigidiser or colloidal silica coating on hot face to prevent fibre erosion in high-velocity gas applications

Disclaimer: values are typical and compiled by Shanker Agencies Pvt. Ltd. from standard industry data and published manufacturer specifications. They are indicative, not a guarantee. Confirm the exact grade datasheet before specifying. For a certified datasheet or quotation, contact info@shankeragencies.com or +91 98999 57888.