Flow Control / Slide Gate Plates

Al₂O₃-C Premium Slide Gate Plates

Al₂O₃-C Premium is the 90-93% Al₂O₃ grade in Shanker Agencies’ slide gate plates range, rated for continuous service to 1650°C.

Al₂O₃-C Premium grade slide gate plates supplied by Shanker Agencies
Grade
Al₂O₃-C Premium
Al₂O₃ content
90-93%
Carbon content
6-10%
Max service temperature
1650°C
Typical service life
12-18 heats

Al₂O₃-C Premium technical specification

Typical values for Al₂O₃-C Premium slide gate plates. Test methods vary by property and product family, so confirm the applicable standard against the manufacturer datasheet before specifying.

Al₂O₃ content
90-93%
Carbon content
6-10%
Typical service life
12-18 heats
Max service temperature
1650°C

Where Al₂O₃-C Premium is used

Ladle slide gate bottom plateLadle slide gate upper & collector nozzleTundish slide gate systemBillet/bloom/slab caster ladleSingle-strand and multi-strand casters

Is Al₂O₃-C Premium right for your application?

  • Rated for continuous service up to 1650°C.
Compare Al₂O₃-C Premium with other grades▾

Compare Al₂O₃-C Premium against every grade SAPL stocks in this family.

Swipe to compare grades

GradeAl₂O₃ contentCarbon contentTypical service lifeMax service temperature
Al₂O₃-C Std85-88%8-12%8-12 heats1600°C
Al₂O₃-C Premiumthis grade90-93%6-10%12-18 heats1650°C
Al₂O₃-ZrO₂-C70-75%-18-25 heats1650°C
ZrO₂-C-8-12%20-30 heats1650°C

Send the drawing, dimensions, application and quantity for Al₂O₃-C Premium slide gate plates. Our technical team reviews the requirement and advises on grade and fulfilment route.

Request Al₂O₃-C Premium Quote
Grade designations & equivalents▾

How Al₂O₃-C Premium is referenced across Indian and export naming conventions.

SAPL grade codeAl₂O₃-C Premium
Alumina content90-93% Al₂O₃
Max service temperature1650°C

Installation notes

  1. 1Inspect slide gate frame and cassette for squareness before fitting plates
  2. 2Ensure plate seating surface is clean and flat, any gap causes steel leakage
  3. 3Apply thin layer of refractory mortar or anti-oxidation paste to back of plate
  4. 4Preheat assembled slide gate to 100–150°C before first heat (electric pre-heater preferred)
  5. 5Check plate wear gauge after each heat, replace when bore erosion exceeds limit
  6. 6Store slide plates in dry conditions, moisture causes cracking during first heat

Disclaimer: values are typical and compiled by Shanker Agencies Pvt. Ltd. from standard industry data and published manufacturer specifications. They are indicative, not a guarantee. Confirm the exact grade datasheet before specifying. For a certified datasheet or quotation, contact info@shankeragencies.com or +91 98999 57888.