50% Al₂O₃ Castable is the 48-52% Al₂O₃ grade in Shanker Agencies’ conventional castables range, rated for continuous service to 1400°C.

50% Al₂O₃ Castable technical specification
Typical values for 50% Al₂O₃ Castable conventional castables. Test methods vary by property and product family, so confirm the applicable standard against the manufacturer datasheet before specifying.
| Property | 50% Al₂O₃ Castable |
|---|---|
| Al₂O₃ content | 48-52% |
| Cement content | 18-22% |
| Bulk density | 2.30 g/cc |
| CCS after 110°C dry | 25 MPa |
| CCS after 1200°C | 45 MPa |
| Max service temperature | 1400°C |
Grade designations and equivalents
How 50% Al₂O₃ Castable is referenced across Indian and export naming conventions.
| SAPL grade code | 50% Al₂O₃ Castable |
| Alumina content | 48-52% Al₂O₃ |
| Max service temperature | 1400°C |
Where 50% Al₂O₃ Castable is used
Full conventional castables range
Compare 50% Al₂O₃ Castable against every grade SAPL stocks in this family.
| Grade | Al₂O₃ content | Cement content | Bulk density | CCS after 110°C dry | CCS after 1200°C | Max service temperature |
|---|---|---|---|---|---|---|
| 40% Al₂O₃ Castable | 38-42% | 20-25% | 2.20 g/cc | 20 MPa | 35 MPa | 1300°C |
| 50% Al₂O₃ Castable | 48-52% | 18-22% | 2.30 g/cc | 25 MPa | 45 MPa | 1400°C |
| 60% Al₂O₃ Castable | 58-62% | 15-20% | 2.45 g/cc | 30 MPa | 60 MPa | 1500°C |
| 70% Al₂O₃ Castable | 68-72% | 15-18% | 2.55 g/cc | 35 MPa | 70 MPa | 1550°C |
| Insulating LD-1.5 | 45-50% | 20-25% | 1.50 g/cc | - | - | 1300°C |
Installation notes
- 1Pre-wet steel formwork to prevent cement-water absorption from the castable mix
- 2Mix with measured water (8–12% by weight) for 4–6 minutes in a pan or paddle mixer
- 3Cast in 200–250 mm layers and vibrate using a 25 mm needle vibrator for 20–30 seconds per layer
- 4Cover with polythene sheet for 24 hrs ambient cure before form removal
- 5Standard dry-out: 25°C/hr to 110°C, hold 8 hrs; then 30°C/hr to operating temperature
- 6For thin sections (< 100 mm): consider hand-pack or gunning instead of casting
Disclaimer: values are typical and compiled by Shanker Agencies Pvt. Ltd. from standard industry data and published manufacturer specifications. They are indicative, not a guarantee. Confirm the exact grade datasheet before specifying. For a certified datasheet or quotation, contact info@shankeragencies.com or +91 98999 57888.